WE Report

Lessons Learned

Lesson Learned





No user selected

Report No.

218

Discipline/Origin

Drilling
No origin

Well

Kallåsen
35/12-6 S

Date created

2019/02/07
2496 days ago

Project Phase

Operational
Project Phase

LL Type/Classification

Equipment
Negative

Transocean Arctic


What happened in Reservoir section:
While RIH with 8 1/2″ BHA, noticed 2 cm missing from one of slip segments. Checked rest of dog collar, found a second damaged segment. Unable to find missing junk, had to assume downhole. Changed from PDC to rock bit as a result. Hydraulic dog collar used for subsequent BHAs.

What Was Planned

RIH with 8 1/2″ BHA

What Was Learned

Design of dog collar slip elements has an inherent weak point where they are recessed to accommodate springs, i.e. sharp 90 degree shoulder.